Spare parts for
induction
Smelting Furnaces
Thyristor, capacitors, control charges, reactors, water-cooled cables and melting parts of the node. We're gonna pick up the markings, the shilds, or the drawing, with a shipment to Kazakhstan.
Which node needs to be restored?

Power thyristors
15 items

Electrothermal capacitors
30 items

DC filter capacitors
6 items

Thyristor assemblies
1 position

Reactors in assembly
1 position

Resistors and RC chains
2 positions

Reactor coils to order
1 position

Control Boards
3 positions

Impulse Boards
1 position

Current Transformers
1 position

Circuit breakers and contactors
8 items

Tilt Control Panels
1 position

Panel instruments and pressure gauges
5 items

Power and Voltage Transformers
3 positions

Water-cooled cables and terminals
10 items

Thyristor coolers
1 position

Copper Tire
1 position

Hoses and manifolds
2 positions

Insulators
1 position

Cooling Fans
2 positions

Isolating Rings
1 position

Induction furnace bodies
8 items

Lining ramming formers
4 positions

Electric tamping
1 position

Furnace tilting gearboxes
11 items
How to choose components for the furnace and converter
For electrical components, the inclusion scheme and operating mode are important, for housings, templates, tires and coils - geometry and connecting dimensions. The capacity of the furnace helps to find a group of parts, but does not replace the verification of the execution of a particular node.
Spare parts catalog
120 itemsPositions are grouped by equipment nodes. Choose the part by marking and operating mode; we check the dimensions and connecting dimensions before ordering.
120 items
















Electrothermal AC capacitor — 600 V 1000 F
600 V In · 1000 μF

Electrothermal AC capacitor — 700 V 1000 F
700 V In · 1000 μF

Electrothermal AC capacitor — 700 V 1091.3 F
700 V In · 1091.3 μF

Electrothermal AC capacitor — 800 V 472.5 F
800 V In · 472.5 μF

Electrothermal AC capacitor — 900 V 295 F
900 V In · 295 μF

Electrothermal AC capacitor — 900 V 196 F
900 V In · 196 μF

Electrothermal AC capacitor — 1000 V 177 F
1000 V In · 177 μF

Electrothermal AC capacitor — 1000 V 180 F
1000 V In · 180 μF

Electrothermal AC capacitor — 1000 V 477.5 F
1000 V In · 477.5 μF

Electrothermal AC capacitor — 1000 V 637 F
1000 V In · 637 μF

Electrothermal AC capacitor — 1100 V 289.4 F
1100 V In · 289.4 μF

Electrothermal AC capacitor — 1200 V 318.3 F
1200 V In · 318.3 μF

Electrothermal AC capacitor — 1250 V 407.4 F
1250 V In · 407.4 μF

Electrothermal AC capacitor — 1250 V 305.6 F
1250 V In · 305.6 μF

Electrothermal AC capacitor — 1250 V 305.6 F
1250 V In · 305.6 μF

Electrothermal AC capacitor — 1500 V 121.3 F
1500 V In · 121.3 μF

Electrothermal AC capacitor — 1600 V 211.4 F
1600 V In · 211.4 μF

Electrothermal AC capacitor — 2000 V 214.9 F
2000 V In · 214.9 μF

Electrothermal AC capacitor — 2500 V 101.9 F
2500 V In · 101.9 μF

Electrothermal AC capacitor — 2500 V 407 F
2500 V In · 407 μF

Electrothermal AC capacitor — 3000 V 50.5 F
3000 V In · 50.5 μF

Electrothermal AC capacitor — 3000 V 106 F
3000 V In · 106 μF

Electrothermal AC capacitor — 3200 V 249 F
3200 V In · 249 μF

Electrothermal AC capacitor — 3300 V 175 F
3300 V In · 175 μF







Water-cooled cable — 150 mm² 3 m
150 mm² · 3 m

Water-cooled cable — 200 mm² 3 m
200 mm² · 3 m

Water-cooled cable — 200 mm² 4 m
200 mm² · 4 m

Water-cooled cable — 150 mm² 3 m
150 mm² · 3 m

Water-cooled cable — 300 mm² 4 m
300 mm² · 4 m

Water-cooled cable — 300 mm² 4,5 m
300 mm² · 4,5 m

Water-cooled cable — 400 mm² 4,5 m
400 mm² · 4,5 m

4 × 200 + 4 × 300 mm² · length 4 / 4,5 m
4 × 200 + 4 × 300 mm² · length 4 / 4,5 m

4 × 300 + 4 × 300 mm² · length 4,5 / 5 m
4 × 300 + 4 × 300 mm² · length 4,5 / 5 m

Control board MPU-2FK
Version, connectors and scheme: check with the installed

Control board MPU-6FK
Version, connectors and scheme: check with the installed

Control board MPU-7
MPU-7 revision, power, connectors and connection scheme agree

Pulse Transformer Board
Separate node marking and number of channels on request

Thyristor water-cooled assembly
Connection scheme and polarity type and number of instruments

Water cooling unit without thyristors
Diameter and flatness of the contact pad height

Reactor assembly
Purpose in the scheme inductance at operating current

Copper Conductor Tires and Jumpers
Thickness and width lengths and bends

Water Cooling System Collector
Overall length and diameter material

Set of hoses and cooling clamps
Inner diameter and length of each branch material

Insulation supports, slats and bushings
Dimensional drawing material and heat resistance class

Power Wire Resistors
Resistance options 20 and 30 Ohm precise performance and power are consistent

Current transformer board DLXH-9.1
Symbol and audit conversion factor with units of measurement


Electromagnetic contactor
Full type application category and working current

Tips for water-cooled cables
Cable sealing contact part shape and dimensions

Remote control tilt furnace with receiver
Drive circuit receiver power

Shield Ammeter
Scale Top Limit Options: 300–1500 A

Input Voltage Shield Voltmeter
Scale Top Limit Options: 450–1000 V

Medium Frequency Voltage Shield Voltmeter
Scale Top Limit Options: 1000–4000 V

Shield Frequency Meter
Scale Top Limit Options: 1000–4000 Hz

Water cooling system pressure gauge
Pressure versions: 0,1–0,5 MPa

Power circuit breaker, 630 A
Current execution of 630 A series and splitter mounts are consistent

Power circuit breaker, 1000 A
Current execution of 1000 A series and splitter mounts are consistent

Power circuit breaker, 1250 A
Current execution of 1250 A series and splitter mounts are consistent

Power circuit breaker, 1600 A
Current execution of 1600 A series and splitter mounts are consistent

Power circuit breaker — current clarification
The value of 1900 A requires confirmation by marking of the installed switch series and disconnector mountings are specified

Power circuit breaker, 3200 A
Current execution of 3200 A series and splitter mounts are consistent

Power Transformer 660/220
Rated voltages: 660/220

Power Transformer 220/17/17
Primary voltage 220 V two secondary voltages according to 17 V

Medium Frequency Voltage Measuring Transformer
Voltage: 1000/100/20

Converter Cabinet Fan
Type, power, performance and installation dimensions are consistent


Reactor repair coils frequency converter to order
For UI series thyristor furnace converter reactors with capacity 100, 150, 250, 350, 500, 750 kg 1

Asbestos insulating rings for induction furnaces
Material: asbestos

Induction furnace housing capacity 250 kg
Furnace capacity: 250 kg

Induction furnace housing capacity 350 kg
Furnace capacity: 350 kg

Induction furnace housing capacity 500 kg
Furnace capacity: 500 kg

Induction furnace housing capacity 750 kg
Furnace capacity: 750 kg

Induction furnace housing capacity 1 t
Furnace capacity: 1 t

Induction furnace housing capacity 1,5 t
Furnace capacity: 1,5 t

Induction furnace housing capacity 2 t
Furnace capacity: 2 t

Induction furnace housing capacity 3 t
Furnace capacity: 3 t


Electrothermal capacitor 0.75-1000-1S
Execution code: 0.75-1000-1S

Electrothermal capacitor 0.75-1000-2.5S
Execution code: 0.75-1000-2.5S

Electrothermal capacitor 0.75-1000-4S
Execution code: 0.75-1000-4S

Electrothermal capacitor 0.75-2000-2.5S
Execution code: 0.75-2000-2.5S

Electrothermal capacitor 1.5-1000-1S
Execution code: 1.5-1000-1S

Electrothermal capacitor 1.5-2000-2.5S
Execution code: 1.5-2000-2.5S
















Spare parts for repair of induction furnace
We supply components for induction melting furnaces and thyristor frequency converters: TECHSEM power thyristors, electrothermal and filter capacitors, control boards and pulse boards, reactors, RC chain resistors, copper tires and insulators.
A separate group - cooling units: thyristor coolers, water-cooled cables and their tips, hoses and collectors. There are furnace casings, insulating rings, lining padding templates, tamping and tilt reducers for the melting unit.
For selection, specify the model of the furnace and converter, part marking and quantity. If the label is not readable, send pictures of the node and the size. The cost and delivery time to Kazakhstan are calculated after the selection of execution.
Help with selection
Send a model of the furnace, a photo of the part and its dimensions. If there is a drawing, enter the position number.
Selection Questions
What do you need to pick up a part without marking?
Send a photo of the assembly node and details separately, basic dimensions and installation location. For electrical components, an on circuit and operating mode are additionally required.
Is the capacity of the oven enough to order?
Capacity helps to find a group of details, but does not confirm the execution. Cases, templates, rings and coils are checked according to the drawing or sample.
How are power thyristors selected?
By family (KPE for phase control, KKE for high-speed switching), average current, voltage class, housing and cooling conditions. For KKE, the shutdown time is additionally taken into account.
What do I need to order a capacitor?
Full labeling from the label: voltage, reactive power, frequency, capacity and section diagram. The reduced code does not determine the size and cooling.
Do you make the details according to the drawing?
Yeah. Reactor coils, furnace casings, lining templates and tires are made to order according to the drawing or sample.
Why is the price indicated on request?