UralInduktor · metallurgical equipment manufacturing and supply
We will call back within 10 minutes

Power Resistors and RC Circuits of Thyristor Converters

Power resistors are used in protective, discharge and auxiliary chains of thyristor converters. The catalog contains cylindrical wire designs. During replacement, the resistance, the allowable average power, the pulse load and the mounting design are checked.

Section Positions

2 positions

Resistors and RC chains: 2 positions in the directory. Execution and completeness are specified during selection.

2 positions

Wire Power Resistors
Resistors and RC chains

Power Wire Resistors

Resistance options 20 and 30 Ohm precise performance and power are consistent

Price on requestRead more

Background

What is the RC chain for?

The protective RC circuit (snabber) consists of a serially connected resistor and capacitor. When turned on parallel to the thyristor, it limits the rate of voltage increase dU / dt and switching overvoltages. The nominals are selected taking into account the parameters of the thyristor, the inductance of the compounds and the switching mode.

The capacitor slows down the build-up of tension on the thyristor. The resistor dampens the oscillations and limits the discharge current of this capacitor when the thyristor is turned on. Components of the RC circuit are selected by pulse mode; the parameters of the power battery of the resonance circuit are not suitable for this.

What data is needed to replace

ComponentCharacteristics for harmonization
ResistorResistance and tolerance; average power; permissible energy, duration and repeatability of pulses; working voltage; design.
RC circuit capacitorCapacity and tolerance; permissible voltage; impulse current; dU/dt; loss and mounting method.
Assembled NodeCircuit, switching frequency, thyristor, placement and length of connections.

Wire Resistors

For the wire resistor, the winding design and its own inductance are significant. In rapid transition processes, they affect the operation of the protective chain. Non-induction performance, resistance and power are specified in the specification for the marking or documentation of the product.

Resistance and impulse load

Two resistors of the same resistance can tolerate short repeating pulses in different ways. For correct selection, load mode is required, including cooling conditions. The indication of only average power also does not describe the permissible energy of a single pulse.

Attach a photo of the labeling of the resistor and the neighboring capacitor, the layout of the node and the dimensions of the mount. If the values are not read, specify the board designation and positional symbols of the components. Replacing the parameters of the RC chain requires checking its operation as part of the converter.

Questions and answers

Can I order only a resistor?

You can apply for a separate component. To check the replacement, the original type and load mode are required.

What parameters are needed to replace the resistor?

Specify the resistance, average power, energy and pulse duration, working voltage and dimensions. Attach the marking and the inclusion scheme.

Selection: resistors and rc-chains

Power resistors are used in protective, discharge and auxiliary chains of thyristor converters. The catalog contains cylindrical wire designs. During replacement, the resistance, the allowable average power, the pulse load and the mounting design are checked.

Help with selection

Send label, photo details and sizes. For details on the drawing, attach a sketch.

Request for selection

Confirm price and configuration

Specify the spare part, model of furnace or converter and quantity. You can attach a photo or drawing.