Power Wire Resistors
Resistance options 20 and 30 Ohm precise performance and power are consistent
Power resistors are used in protective, discharge and auxiliary chains of thyristor converters. The catalog contains cylindrical wire designs. During replacement, the resistance, the allowable average power, the pulse load and the mounting design are checked.
Resistors and RC chains: 2 positions in the directory. Execution and completeness are specified during selection.
2 positions

Resistance options 20 and 30 Ohm precise performance and power are consistent

The protective RC circuit (snabber) consists of a serially connected resistor and capacitor. When turned on parallel to the thyristor, it limits the rate of voltage increase dU / dt and switching overvoltages. The nominals are selected taking into account the parameters of the thyristor, the inductance of the compounds and the switching mode.
The capacitor slows down the build-up of tension on the thyristor. The resistor dampens the oscillations and limits the discharge current of this capacitor when the thyristor is turned on. Components of the RC circuit are selected by pulse mode; the parameters of the power battery of the resonance circuit are not suitable for this.
| Component | Characteristics for harmonization |
|---|---|
| Resistor | Resistance and tolerance; average power; permissible energy, duration and repeatability of pulses; working voltage; design. |
| RC circuit capacitor | Capacity and tolerance; permissible voltage; impulse current; dU/dt; loss and mounting method. |
| Assembled Node | Circuit, switching frequency, thyristor, placement and length of connections. |
For the wire resistor, the winding design and its own inductance are significant. In rapid transition processes, they affect the operation of the protective chain. Non-induction performance, resistance and power are specified in the specification for the marking or documentation of the product.
Two resistors of the same resistance can tolerate short repeating pulses in different ways. For correct selection, load mode is required, including cooling conditions. The indication of only average power also does not describe the permissible energy of a single pulse.
Attach a photo of the labeling of the resistor and the neighboring capacitor, the layout of the node and the dimensions of the mount. If the values are not read, specify the board designation and positional symbols of the components. Replacing the parameters of the RC chain requires checking its operation as part of the converter.
You can apply for a separate component. To check the replacement, the original type and load mode are required.
Specify the resistance, average power, energy and pulse duration, working voltage and dimensions. Attach the marking and the inclusion scheme.
Power resistors are used in protective, discharge and auxiliary chains of thyristor converters. The catalog contains cylindrical wire designs. During replacement, the resistance, the allowable average power, the pulse load and the mounting design are checked.
Send label, photo details and sizes. For details on the drawing, attach a sketch.