Water-cooled power cables for induction furnaces

Flexible water-cooled cables for power connections of induction equipment. They are selected by electric load, operating frequency, track length, tips and water circuit. For the mobile connection, the operating positions of the kiln and the bending position are further taken into account.

Section Positions

10 items

Water-cooled cables and tips: 10 positions in the catalog. Execution and completeness are specified during selection.

10 items

Background

Single Cables and Kits

PositionParameters from the nomenclature
Water-cooled cable150 mm²; 3 m; converter nodes
Water-cooled cable200 mm²; 3 m; converter nodes
Water-cooled cable200 mm²; 4 m; converter nodes
Water-cooled cable150 mm²; 3 m; capacitor connection
Water-cooled cable300 mm²; 4 m; capacitor connection
Water-cooled cable300 mm²; 4,5 m; capacitor connection
Water-cooled cable400 mm²; 4,5 m; capacitor connection
Connection of water-cooled cables4 × 200 + 4 × 300 mm²; length 4 / 4,5 m
Connection of water-cooled cables4 × 300 + 4 × 300 mm²; length 4,5 / 5 m

The section is specified for a separate cable. The entry 4 × 200 + 4 × 300 mm² describes the composition of the bundle: four cables of each cross section. The measuring points of length and the length of each branch are agreed upon in the drawing.

Tips for water-cooled cables

The tips are selected according to the design of the conductor, the shape of the contact part and the connection of cooling water. A separate page will help to prepare the dimensions for ordering tips or coordinating the cable assembly.

Dimensions, tips and cable track

Cables of the same section can differ in the form of contact tips, the location of the holes, the orientation of the fittings and the internal design. The dimensions of both ends and the position of their contact planes relative to each other are required for installation on a regular place.

Too short a cable can experience tension when the furnace moves. Excessive length changes the track and bending conditions. In the application, it is important to show the extreme operating positions of the equipment and indicate the points between which the required length is measured.

Load and Cooling

The permissible current cannot be reliably assigned only by the cross-sectional area. For medium frequency connection, the frequency, load mode, core design and heat dissipation conditions are required. The cooling parameters are checked for the selected cable and its actual connection.

If the cable is overheated, attach information about the place of heating, contact status, flow rate and water temperature. This data will help in the selection of replacement and examination of the connection.

What should be on the sketch

  • Length with designated measuring points; for a ligament, the length of each branch.
  • The dimensions of the contact sites, the diameter and pitch of the holes.
  • Mutual orientation of tips and fittings.
  • Type of water connection and information about the available circuit.
  • Cable track, mobile areas, size restrictions.

How to agree on a set

In the specification of the bundle, the number of cables, sections, lengths and the purpose of each branch are recorded. Separately, the composition of the tips, hoses, adapters and fasteners, if they are needed, is indicated. The photo of the finished bundle does not determine its completeness for another installation.

Questions and answers

Can I order on the old cable?

The sample or measurements help to harmonize the mechanics. In addition, operating current, frequency and cooling conditions are required.

Do you have 150 mm² cables?

There are 150 mm² length 3 m cross-section cables in the catalog. The purpose and tips of a particular option are specified when ordering.

Will the cable be of a different length?

The change in length is checked by the route, the movement of the equipment and the electrical conditions of the connection.

How is the cost of the bundle calculated?

By composition: the number of individual cables, their section, length, tips and agreed additional elements.

Calculate cable or bundle

Send photos of both tips, general view of the track and measurements. Specify the number, operating current and frequency. If part of the dimensions is unknown, note this in the request to agree on a way to clarify them.

Selection: water-cooled cables and tips

Flexible water-cooled cables for power connections of induction equipment. They are selected by electric load, operating frequency, track length, tips and water circuit. For the mobile connection, the operating positions of the kiln and the bending position are further taken into account.

Help with selection

Send label, photo details and sizes. For details on the drawing, attach a sketch.

Request for selection

Confirm price and configuration

Specify the spare part, model of furnace or converter and quantity. You can attach a photo or drawing.