Copper Conductor Tires and Jumpers
Thickness and width lengths and bends
Copper tires connect power devices, reactors, capacitor units and other elements of the induction furnace converter. The tyre is selected according to the drawing or size of the sample, taking into account the current, frequency and cooling conditions. The contact pads and the location of the mounting holes are consistent with the overall geometry.
Copper tires: 1 position in the catalog. Execution and completeness are specified during selection.
1 position

Thickness and width lengths and bends


Tires in the converter work in AC network circuits, DC link and mid-frequency output circuit. With alternating current, the surface effect and the influence of adjacent conductors change the distribution of current across the section. Therefore, when choosing a bus, the frequency and relative location of the conductors are taken into account.
The geometry of the compounds affects the inductance of the current circuit. When replaced, the mutual arrangement of conductors, contact platforms and insulating supports provided by the scheme is maintained. The transfer of connections requires an assessment of the electrical and mechanical mode.
Hard tires are performed with contact pads and bolt attachment holes. The copper mark, cross section, coating and bending dimensions are specified according to the drawing. The contact surfaces and tightening of the connection must be consistent with the documentation of the node.
Hard conductors are used where the connection points retain a mutual position. When moving or vibrating, the design may include a flexible connection or a water-cooled cable. It is impossible to change the type of connection without coordinating the mechanics and electrical parameters.
Send a drawing or photos of the part with dimensions and marked contact surfaces. Specify the number of identical parts, location in the scheme and requirements for completeness: only a tire, a tire with a fastener or a node with insulating supports.
From the photo you can determine the constructive type. To agree on the details, dimensions, electrical mode and contact requirements are required.
Yeah. For medium frequency circuits, the frequency and relative location of the conductors affect the loss and heating.
Copper tires connect power devices, reactors, capacitor units and other elements of the induction furnace converter. The tyre is selected according to the drawing or size of the sample, taking into account the current, frequency and cooling conditions. The contact pads and the location of the mounting holes are consistent with the overall geometry.
Send label, photo details and sizes. For details on the drawing, attach a sketch.