Water cooling unit without thyristors
Diameter and flatness of the contact pad height
The water cooler diverts heat from the body of the power thyristor to the converter cooling system. It is included in the contact assembly of the disk device and is selected according to the geometry of the housing, the conditions of the heat sink and the connecting dimensions. To order send a photo of the cooler on both sides and the designation of the thyristor.
Thyristor coolers: 1 catalog entry. The performance and completeness shall be specified upon selection.
1 position

Diameter and flatness of the contact pad height

Coolers are installed in rectifier and inverter power assemblies. With bilateral cooling, heat is transferred through both main contact surfaces of the device. The body temperature, flow rate and water temperature affect the allowable load of the thyristor. Passport current at a given body temperature is not a guaranteed current under any cooling conditions.
A block of three cylindrical coolers with fittings, end supports and isolated coupling elements is shown. The thyristors in the block shown are not installed. The parameters of the internal channels, thermal resistance and allowable pressure are specified according to the documentation of the selected execution; the direction of the duct is determined by the hydraulic circuit.
| Parameter | What is needed |
|---|---|
| Diameter and flatness of contact surfaces | Compatibility with the thyristor body and uniform thermal contact. |
| Cooler thickness and total assembly height | Compatibility with the working flow of the clamp. |
| Type, size and arrangement of fittings | Connection of hoses without bending and tension. |
| Thermal resistance in the given mode | Checking the temperature of the body at estimated losses. |
| Flow rate, pressure difference, water temperature | Harmonization of the cooler with the pumping system. |
| Material and water requirements | Compatibility with other elements of the circuit. |
The cooler can simultaneously perform the function of a current-guided contact. Therefore, mechanical compatibility and tightness do not replace electrical connection checks. The condition of the working surface, the insulation of water compounds and the material of the mating parts are taken into account together with the thermal parameters.
For an existing node, data on the water temperature at the inlet and outlet, branch flow and protection triggers are useful. This information helps to check whether the problem is related to the cooler, the general lack of duct or the state of the contact assembly.
Diameter is not enough. You need to check the contact surface, height, channels, fittings, thermal characteristics and permissible pressure.
The composition of the replacement is determined by the state of assembly. In the application, specify one detail or set of coolers per node is required.
The cooling unit is equipped without power thyristors. For thyristor assembly, semiconductor devices, their location and the electrical connection scheme are additionally coordinated.
The water cooler diverts heat from the body of the power thyristor to the converter cooling system. It is included in the contact assembly of the disk device and is selected according to the geometry of the housing, the conditions of the heat sink and the connecting dimensions. To order send a photo of the cooler on both sides and the designation of the thyristor.
Send label, photo details and sizes. For details on the drawing, attach a sketch.