UralInduktor · metallurgical equipment manufacturing and supply
We will call back within 10 minutes

Induction Melting Furnace Frequency Converter

The thyristor frequency converter supplies the induction melting furnace with the alternating current of the required frequency. It converts the power supply network and controls the electrical installation mode. The purpose of the spare part is determined by its place in the power scheme, control system or cooling circuit.

Energy path in the model scheme

Power supply rectifier DC link thyristor inverter output resonant circuit and matching elements if provided furnace inductor. This is a functional sequence, not an installation diagram of a particular installation. The composition of the DC link and the location of the capacitors depend on the converter circuit.

NodeAppointmentRelated spare parts
StraightenerConverting network AC to DC; regulating in a managed circuit.Phase-controlled thyristors, power assemblies, control and protection circuits.
DC LinkThe connection of the rectifier with the inverter and the formation of a current or voltage mode.Smoothing reactor; filter capacitors in their presence in the scheme.
InverterConversion of direct current link energy to alternating current of operating frequency.Fast-acting thyristors, impulse boards, protective circuits.
Resonance circuitCoordinated operation of inductive and capacitive elements in working mode.Electrothermal AC-capacitors, inductor, power connections.
Management and measurementFormation of control pulses, feedback and execution of protection algorithms.Control boards, pulse transformers, measuring boards.
Cooling and installationHeat dissipation, water distribution, electrical and mechanical connections.Coolers, hoses, manifolds, clamps, tires and insulators.

Rectifiers and inverter thyristors

TECHSEM separates the KPE family for phase control and the KKE family with quick shutdown. For the inverter, the dynamic characteristics and recovery time of the locking ability are especially important. The KPE and KKE thyristors are not switched off by taking a signal from the control electrode. To turn off, the current must be reduced below the holding current, after which time is required to restore the locking ability under the circuit switching conditions.

Reactor and capacitors perform different tasks

The smoothing reactor reduces the current pulsations in the corresponding link. Electrothermal capacitors work in AC circuits, including in the resonance circuit. The DC filter capacitor is selected for the DC circuit. The presence of a large capacitor battery in the furnace does not mean that it is included in the DC link.

Control Boards and Measuring Chains

The control board sets the pulse moments and processes the input signals according to the converter algorithm. Impulse transformers transmit control pulses and provide the circuit solution. The measuring circuits tell the system about currents and voltages. When replacing check the audit, power, pin and signal parameters.

Relation of cooling to electric load

Losses in thyristors, conductors and reactors are released as heat. Water-cooled units take it to the general circuit, and clamping devices provide the necessary contact in semiconductor assemblies. The current value of the device should be considered together with the temperature conditions indicated in his passport.

How to determine the necessary spare part

  • Find a position on the electrical or hydraulic circuit.
  • Take pictures of the markings, connections and the general view of the node.
  • Determine if you need a separate part, assembly or set of ZIP.
  • Compare passport parameters, design and actual mode.
  • Record consistent execution and completeness in the specification.

Questions and answers

Do all frequency converters have the same scheme?

Oh, no. There are different number of rectifier pulsations, inverter circuit, way of matching with the load and control system. The functional description helps to navigate, but does not replace the installation documentation.

Can you determine the cause of the accident by one failed thyristor?

One refusal does not establish a cause. For evaluation, information about switching, control, cooling, load and protection triggers is required.

Why specify the place of installation of the part?

The same trade name may refer to different regimes. The space in the circuit determines which electrical and design parameters to check.

Help with selection

Send the model of furnace and converter, part marking and quantity. For details on the drawing, attach a sketch or photo of the sample.

Spare parts catalog

All 120 partition items are collected in the directory with filters by node and group.

Go to catalog

Request for selection

Confirm price and configuration