1. Identify a rectifier or inverter
The TECHSEM KPE families are phase-controlled, KKE are fast-acting thyristors. For a controlled rectifier and inverter, the priorities of choice differ. Write down the place of installation according to the scheme; the name of the furnace does not replace the purpose of a particular valve.
2. Compare current in the same conditions
IT(AV) is the average open current at the specified current and cooling pattern. In the KPE reviewed, it is given at Tc = 70 °C, in KKE = Tc = 55 °C; for both rows, a two-way cooling and semi-synusoid current with a conductivity angle of 180° at 50 Hz is specified. The currents of the different instruments are compared under the same rationing conditions.
Passport IT (AV) cannot be directly considered an acceptable current of a particular medium-frequency inverter. For its mode, losses, switching and heat calculation are checked. Therefore, the application indicates the full designation of the thyristor, and not only the rounded current.
3. Clarify tension and dynamics
VDRM is a repeated pulse voltage in the closed state, VRRM is a repeated pulse reverse voltage. A specific class is selected according to the requirements of the converter. KKE also requires tq shutdown time under conditions compatible with inverter calculation. The family interval does not replace the selected tq variant.
Example: Y65KKE has IT(AV) 2080 A and tq 18–50 mx, Y70KKE - 2240 A and tq 30–60 mx. The second has more passport average current, but the off time range is different. The conclusion about interchangeability only on average current would be incomplete.
4. Check the control electrode, housing and clamp
| Parameter | Y65KKE | Y70KKE |
|---|---|---|
| Housing | KT60cT | KT60cT |
| IT(AV), Tc = 55 °C | 2080 A | 2240 A |
| tq | 18-50mx | 30-60mx |
| IGT at VA = 12 V, IA = 1 A, 25 °C | 40-400 mA | 40-450 mA |
| Fm | 27-34 kN | 30-40 kN |
Even the general body code KT60cT does not make the control and clamping requirements the same. IGT values are the unlock parameters in the test conditions, and not the ready setting of the operating pulse amplitude. The range of Fm is the clamping force, it cannot be replaced by the moment of tightening the bolt without the documentation of the node.
5. Fix the replacement conditions
- Original and proposed complete markings.
- Comparison of voltage, current, dynamics and control.
- Coordinated drawing of the body and the clamping unit.
- Cooling conditions and the composition of the necessary additional parts.
- Documents and inspection procedure after installation according to the requirements of the equipment.
Questions and answers
Is it possible to determine the operating frequency by 1/tq?
No. tq is one of the switching parameters. The frequency and allowable mode depend on the circuit, the time of the backshift, the load and the stock.
Can KK and KKE be considered a single designation?
No, without a passport, this is only a possible connection of trade marks. In the order you need to keep the original marking and confirm the specific execution.
Does more pressure improve cooling?
The pressure should correspond to the documentation of the product and the node. Going beyond a set range is not a way to improve performance.
Check selected thyristor
Go to the family card and attach its designation to the request along with the original passport. The specification indicates the full custom designation, electrical parameters and body design.