UralInduktor · metallurgical equipment manufacturing and supply
We will call back within 10 minutes

Current transformers and measuring boards frequency converter

Current transformers and measuring boards form signals to control the mode and operation of the thyristor converter control system. They are used in measuring circuits, feedback circuits and protection according to the frequency converter scheme. Selection requires the coordination of the measured signal, the conversion factor and the input of the connected board.

Section Positions

1 position

Current transformers: 1 position in the catalog. Execution and completeness are specified during selection.

1 position

Background

Purpose in Converter

The measuring channel transmits to the control system a signal proportional to the current in the controlled circuit. It is used to regulate, limit current or protect. When selecting, it is important to specify the place of installation of the sensor and the input of the board to which it is connected.

A current transformer measures alternating current within its frequency range. It does not transmit a constant component; it can cause magnetization and saturation of the core. To measure direct current, a sensor of the corresponding principle of action is needed. The type of meter is selected according to the shape of the signal and the circuit section.

Current transformer board DLXH-9.1

DLXH-9.1 is a board with three measuring current transformers. For replacement, you need the designation and revision of the board, the scheme of secondary circuits and the characteristics of the inputs of the control system. Mark "5:0.1" specify in the application in full; conversion factor with units of measurement is specified by the passport of the installed node.

Measurement channel parameters

  • Type of measured current, frequency, signal shape and operating range.
  • Conversion factor with units, allowable output load and accuracy.
  • Polarity, phase error, pinning and connection to the control board.
  • Insulation, opening or conclusions of the primary chain, dimensions and anchorages.
  • Marking and revision of the entire board, as well as the scheme of secondary chains.

Questions and answers

Can I replace DLXH-9.1 with a board with similar connectors?

Matching connectors is not enough. It is necessary to check the scheme, conversion coefficients, polarity, output load and audit.

What do I need to photograph for selection?

The general type of board on both sides, all inscriptions, connectors and connected wires with designations. The photo is supplemented with a scheme of the measuring channel, if available.

Selection: current transformers

Current transformers and measuring boards form signals to control the mode and operation of the thyristor converter control system. They are used in measuring circuits, feedback circuits and protection according to the frequency converter scheme. Selection requires the coordination of the measured signal, the conversion factor and the input of the connected board.

Help with selection

Send label, photo details and sizes. For details on the drawing, attach a sketch.

Request for selection

Confirm price and configuration

Specify the spare part, model of furnace or converter and quantity. You can attach a photo or drawing.