UralInduktor · metallurgical equipment manufacturing and supply
We will call back within 10 minutes

Part illustration. Configuration and supply scope are confirmed during selection.

Power thyristors

Thyristor TECHSEM Y70KKE

Switching current in the frequency converter.

Main parameters
2240 A 55 °C
Catalogue designation
TH-15
Equipment assembly
Power thyristors
Catalogue group
Power section

Price on request

Price and delivery time are confirmed for the selected configuration

Purpose and features

Switching current in the frequency converter.

IT(AV) 2240 A; Tc 55 °C; bilateral cooling; semi-sine current with 180° at 50 Hz; Tj 125 °C. VDRM/VRRM 800-1800 V Vq 30-60mx.

Configuration and specifications

Catalogue designationTH-15
SpecificationsIT(AV) 2240 A; Tc 55 °C; bilateral cooling; semi-sine current with 180° at 50 Hz; Tj 125 °C. VDRM/VRRM 800-1800 V Vq 30-60mx.
AppointmentSwitching current in the frequency converter.
Data for selectionVoltage class, housing, pressing, cooling and control parameters. Additionally, the required shutdown time tq.
Equipment assemblyPower thyristors
Catalogue groupPower section

Purpose Y70KKE

Y70KKE is used in inverters of induction heating plants. In the frequency converter of the melting furnace, the device is selected according to the switching and time mode available to restore the locking ability.

Passport characteristics

ParameterSignificance and Conditions
ManufacturerTECHSEM
FamilyY70KKE
TypeFast-acting thyristor
IT(AV)2240 A
Terms of IT(AV)Tc = 55 °C; double-sided cooling; half-sine current with a conduction angle of 180° at 50 Hz; Tj = 125 °C
VDRM/VRRM, repetitive impulse voltages800–1800 V; class is chosen when ordering
tq30–60 mx; execution is selected according to inverter requirements
Terms of tqITM = 2000 A; tp = 4000mx; VR = 100 V; dU/dt = 30 V/mx; di/dt = -− 20 A/mx Tj = 125 °C
HousingKT60cT
Fm, pressing force30-40 kN
IGT, Unlocking Control Current40-450 mA
VGT, Unlocking Voltage Control0,9–4,5 V
IGT and VGT TermsVA = 12 V; IA = 1 A; temperature 25 °C
ITSM, shock current23 CA; semi-sinusoidal pulse 10 ms, Tj 125 °C
Tvj, transition temperature−40…+125 °C
Mass by passport880 g

Selection features Y70KKE

In Y70KKE, the shutdown time is 30–60 mx, the clamping force is 30–40 kN. For Y65KKE in the same housing KT60cT specified 18–50 mx and 27–34 kN. When replacing, you need to check the time allotted by the circuit for shutdown, and the characteristics of the clamping node.

Comparison with neighboring families

FamilyIT(AV), Atq,mxHousing
Y65KKE208018–50KT60cT
Y70KKE224030–60KT60cT

What to agree before ordering

  • Full labeling of the installed product and the selected voltage class.
  • Required tq variant and inverter switching mode.
  • Execution of the body, contact surfaces and clamping unit.
  • Requirements for the control electrode circuit and compatibility with the control board.
  • Quantity, composition of delivery, documentation and required time.

Passport and dimensional drawing

Ask Y70KKE

Send photo of the original label and specify Y70KKE, required voltage class, tq, quantity and converter parameters. If the analogue is considered, attach the passport of the replaceable thyristor.

Request for selection

Confirm price and configuration

Specify the spare part, model of furnace or converter and quantity. You can attach a photo or drawing.