Electrothermal AC capacitor — 600 V 1000 F
600 V In · 1000 μF
Water-cooled electrothermal capacitors operate in resonant circuits of induction heating and smelting. Below are the 24 variants with electric characteristics and six more designations for selection by full labeling. When replacing, the voltage, reactive power, frequency, capacity and connection scheme of the sections are checked.
Electrothermal capacitors: 30 positions in the catalog. Execution and completeness are specified during selection.
30 items

600 V In · 1000 μF

700 V In · 1000 μF

700 V In · 1091.3 μF

800 V In · 472.5 μF

900 V In · 295 μF

900 V In · 196 μF

1000 V In · 177 μF

1000 V In · 180 μF

1000 V In · 477.5 μF

1000 V In · 637 μF

1100 V In · 289.4 μF

1200 V In · 318.3 μF

1250 V In · 407.4 μF

1250 V In · 305.6 μF

1250 V In · 305.6 μF

1500 V In · 121.3 μF

1600 V In · 211.4 μF

2000 V In · 214.9 μF

2500 V In · 101.9 μF

2500 V In · 407 μF

3000 V In · 50.5 μF

3000 V In · 106 μF

3200 V In · 249 μF

3300 V In · 175 μF

Execution code: 0.75-1000-1S

Execution code: 0.75-1000-2.5S

Execution code: 0.75-1000-4S

Execution code: 0.75-2000-2.5S

Execution code: 1.5-1000-1S

Execution code: 1.5-2000-2.5S


The table shows the 24 electric options. When ordering, the full designation, section scheme, dimensions and attachments are agreed. The availability and delivery time are specified for the selected execution.
| U AC, B | Q,Qar | f, Hz | C, uCP | Sections |
|---|---|---|---|---|
| 600 | 1131 | 500 | 1000 | 8 |
| 700 | 1539 | 500 | 1000 | 8 |
| 700 | 1680 | 500 | 1091,3 | 1 |
| 800 | 1900 | 1000 | 472,5 | 1 |
| 900 | 1500 | 1000 | 295 | 6 |
| 900 | 2000 | 2000 | 196 | 8 |
| 1000 | 780 | 700 | 177 | 6 |
| 1000 | 792 | 700 | 180 | 6 |
| 1000 | 1500 | 500 | 477,5 | 6 |
| 1000 | 2000 | 500 | 637 | 1 |
| 1100 | 2200 | 1000 | 289,4 | 1 |
| 1200 | 2880 | 1000 | 318,3 | 8 |
| 1250 | 2000 | 500 | 407,4 | 8 |
| 1250 | 3000 | 1000 | 305,6 | 8 |
| 1250 | 3000 | 1000 | 305,6 | 1 |
| 1500 | 1200 | 700 | 121,3 | 1 |
| 1600 | 3400 | 1000 | 211,4 | 1 |
| 2000 | 2700 | 500 | 214,9 | 6 |
| 2500 | 2000 | 500 | 101,9 | 6 |
| 2500 | 8000 | 500 | 407 | 1 |
| 3000 | 2000 | 700 | 50,5 | 1 |
| 3000 | 6000 | 1000 | 106 | 1 |
| 3200 | 8000 | 500 | 249 | 1 |
| 3300 | 6000 | 500 | 175 | 1 |
U AC is the nominal operating voltage at the capacitor terminals. It may differ from the voltage supply network of the furnace. The reactive power Q is expressed in quar, the active power of the furnace is in kW. The frequency f and the capacity C must correspond to the working circuit; for the sectioned product, the capacity of each section and the connection of the terminals are specified.
Example from the table: 1250 V, 3000 quar, 1000 Hz and 305,6 F meet with one and eight sections. The nominal U, Q, f, and total capacity are the same, but the inference scheme and connectivity are different. To replace it is not enough to choose a string with the same four numbers.
Presented AC capacitors have a polypropylene film dielectric, aluminum foil coatings, copper terminals, and water cooling tubes. Impregnation is performed with insulating oil without polychlorinated biphenyls (PCBs). To order specify the material of the housing and its electrical connection with the terminals or insulation from the current-guided parts.
The drawing should record the dimensions, supports, the location of the conclusions, fittings and the permissible mounting position. Water parameters and consumption are checked according to the product documentation and the capabilities of the current system.
In the documentation on electrothermal capacitors there are designations RFM and RAM. The letters of the series alone are not enough to select by frequency or design. To request, keep the label as a whole and attach a nameplate. For each row of the table, when ordering, the full factory designation is specified: it is impossible to determine the execution of terminals and the body by a combination of values without a drawing.
For a separate replacement, the data of the capacitor itself and its place in the battery are needed. Indicate how sections and neighboring products are connected. If the capacity, frequency or connection scheme changes, a check of the entire resonant circuit is required; a simple replacement for the size of the housing does not provide such a check.
For this table, the reactive power in quar is used. If the initial statement says KVA, attach a name: the designation and physical value must be checked.
Changing the capacity changes the contour parameters. The possibility of replacement is confirmed by the calculation and requirements of the converter, and not only by the voltage reserve.
They are designed for different regimes. The coincidence of the capacitance and the numerical value of the voltage does not confirm the suitability of the DC capacitor in the AC circuit.
Agreed U,Q,f,C,sections,conclusion design,body,quantity and delivery terms. To calculate, send parameters or a photo of the label.
Send a photo of the marking, the general view and the scheme of the conclusions. If you select a row of a table, specify all its parameters and the number of sections. Full execution, cost and time are fixed in the offer.
Water-cooled electrothermal capacitors operate in resonant circuits of induction heating and smelting. Below are the 24 variants with electric characteristics and six more designations for selection by full labeling. When replacing, the voltage, reactive power, frequency, capacity and connection scheme of the sections are checked.
Send label, photo details and sizes. For details on the drawing, attach a sketch.