Control board MPU-2FK
Version, connectors and scheme: check with the installed
Control boards MPU-2FK, MPU-6FK and MPU-7 are used in thyristor converters of induction melting furnaces in accordance with the equipment scheme. The board generates control signals and interacts with measurement circuits and protections. When replacing, the revision, power, connector assignment and signal parameters are agreed.
Control boards: 3 positions in the directory. Execution and completeness are specified during selection.
3 positions

Version, connectors and scheme: check with the installed

Version, connectors and scheme: check with the installed

MPU-7 revision, power, connectors and connection scheme agree



| Fees | Appointment | What to check when selecting |
|---|---|---|
| MPU-2FK | Control thyristor converter in the appropriate version. | Audit, power, pin, circuit and compatible nodes. |
| MPU-6FK | Control thyristor converter in the appropriate version. | Board version, connector assignment and signal parameters. |
| MPU-7 | Control thyristor converter in the appropriate version. | MPU-7 revision, power supply, connection scheme, input and output parameters. |
When replacing the board, check the power supply, feedback inputs, thyristor control outputs and protection chains. Boards with the same main designation may have hardware revisions and assignment of contacts. After upgrading the converter, the selection is carried out according to the current cabinet scheme.
When replacing, you need to understand which functions are implemented by the board itself, and which ones are implemented by separate modules. You can not transfer the settings, assignment of jumpers and connectors from a similar photo without the documentation of the selected execution.
If the oven does not start, report the reported accidents, power status, and events before stopping. The failure of the board is confirmed by diagnostics; this information will help determine whether you need to replace the board or check other nodes.
The order indicates the full designation, audit, completeness, available documentation and terms of delivery. If you want to adapt, test or configure, its composition is consistent with a separate line. When delivering a single board, additional pulse modules and cables should not be implied.
To replace MPU-2FK with MPU-6FK, you need to compare power, input and output signals, pin and control algorithm. The designations of these boards do not indicate direct interchangeability.
You need MPU-7 designation, revision, photos of both sides and connectors, power and connection scheme. Compatibility is checked according to the installed converter.
The photo helps to define the family. To confirm compatibility, you may need a version, scheme and parameters of the chains.
Yes, the reserve request is generated according to the established configuration. In the statement of the ZIP, it is necessary to keep the audit and the binding of the board to a specific furnace.
Send labeling, revision and photos of the fee. Specify if you need an accurate replacement, backup, or option check for an upgraded converter.
In the measuring channels of the converter, separate circuit boards of current transformers can be used, including DLXH-9.1. When selecting, check the conversion factor, the load of the secondary chains and the connection to the main control board.
Control boards MPU-2FK, MPU-6FK and MPU-7 are used in thyristor converters of induction melting furnaces in accordance with the equipment scheme. The board generates control signals and interacts with measurement circuits and protections. When replacing, the revision, power, connector assignment and signal parameters are agreed.
Send label, photo details and sizes. For details on the drawing, attach a sketch.