Automatic circuit breakers and contactors for frequency converter
Automatic switches and contactors are used in the supply and auxiliary circuits of the thyristor converter. The machine performs the protection functions provided by its characteristics, and the contactor provides controlled load switching. These devices are selected according to the purpose of the chain and the calculation mode.
Section Positions
8 itemsAutomatic machines and contactors: 8 positions in the catalog. Execution and completeness are specified during selection.
8 items


Electromagnetic contactor
Full type application category and working current

Power circuit breaker, 630 A
Current execution of 630 A series and splitter mounts are consistent

Power circuit breaker, 1000 A
Current execution of 1000 A series and splitter mounts are consistent

Power circuit breaker, 1250 A
Current execution of 1250 A series and splitter mounts are consistent

Power circuit breaker, 1600 A
Current execution of 1600 A series and splitter mounts are consistent

Power circuit breaker — current clarification
The value of 1900 A requires confirmation by marking of the installed switch series and disconnector mountings are specified

Power circuit breaker, 3200 A
Current execution of 3200 A series and splitter mounts are consistent
Background

Apparatus for supply and auxiliary chains
In power supply chains, switches of the corresponding current execution and disconnecting power are used. Modular machines are used to protect auxiliary circuits, contactors are used for remote load switching. For the switch, the switch and its settings are checked, for the contactor, the application category and the power supply of the coil.
Circuit Breaker Options
| Parameter | What is verified |
|---|---|
| Number of poles and type of chain | AC or DC, operating voltage and circuit switching. |
| Nominal current and dissipation characteristic | Working load current, starting processes and protection of conductors. |
| Disconnecting ability | Compliance with the expected short circuit current at the installation site. |
| Configuration | Installation, dimensions, cross-section of connected conductors and additional contacts. |
Contactor Settings
For the contactor indicate the nominal operating voltage, category of application and current in this category. For example, the categories AC-1 and AC-3 refer to different load conditions; the permissible currents for them may vary. Separately check the voltage of the coil, the kind of current of its supply and the composition of auxiliary contacts.
- Type of switching load and frequency of operations.
- Number of force poles and required normally open or normally closed auxiliary contacts.
- Powering the control coil and the presence of coordinated protective elements.
- Mounting dimensions, terminals, locks and compatibility with the existing scheme.
Relation to the protection of power thyristors
The protection of power thyristors is checked separately from the protection of auxiliary chains. Harmonization of automatic machines, high-speed protective devices and electronic protections is determined by the converter project. With repeated shutdowns, the cause is first established; an increase in the nominal current of the automaton can leave the circuit without the required protection.
Request for replacement
Send a separate photo of the front marking of the machine or contactor, the coil name and the designation of the device on the diagram. For the contactor, it is useful to specify the number of auxiliary contacts involved. In the proposal, it is necessary to fix the exact series and execution.
Questions and answers
Can I determine the nominal value of the machine by the general type?
Oh, no. For selection, you need a readable marking, the number of poles, the nominal current, the characteristics of the shutdown and the disabling ability.
Is it possible to pick up a contactor only by current?
Oh, no. Need application category, power circuit voltage, coil power, contacts and switching conditions.
Selection: vending machines and contactors
Automatic switches and contactors are used in the supply and auxiliary circuits of the thyristor converter. The machine performs the protection functions provided by its characteristics, and the contactor provides controlled load switching. These devices are selected according to the purpose of the chain and the calculation mode.
Help with selection
Send label, photo details and sizes. For details on the drawing, attach a sketch.