Heat treatment furnace lining and heating element selection

When choosing a thermal furnace, it is important to coordinate not only the size of the chamber and the power, but also the lining materials, the type of heaters, the working environment and the control system. Below are options from the UI-IP, UI-IP, UI-IP, UI-IP and UI-IP and questions that help to compile an accurate technical task.

From what perform fibrous insulation

These series provide ceramic fiber, materials based on aluminum oxide, its high-purity and composite versions, and for some high-temperature versions - fiber based on zirconium oxide. The additional layer is made of fibrous heat-insulating material. 800 and 1000 °C are equipped with ceramic fiber modules.

Furnace class, °CMaterial of fibrous elementsHeaters by complete set
800 / 1000Ceramic fibreFeCrAl wire
1200Alumina-based fibreNiCr wire or SiC
1400Alumina-based composite fibreSiC rods
1600High-purity alumina fibreMoSi₂ rods
1700High-purity alumina composite fibreMoSi₂ rods
1800Zirconia-based fibreMoSi₂ rods

In UI-MPVP, low-temperature metal heaters are tape-shaped. For UI-MWTP, the resulting matrix ends with the execution of 1700 °C; the 1800 °C variant from this table is not transferred to the vacuum series. We consider the configuration with a molybdenum belt heater separately.

This is a list of options, not a single design of all furnaces. The layered composition of walls, vaults, doors and pods, thicknesses, fasteners and supports for products are indicated in the specification. For a protective atmosphere and vacuum, we further agree on the applicability of materials at a given temperature and pressure.

Which means FeCrAl, NiCr, SiC and MoSi₂

FeCrAl is an iron chromaluminium alloy and NiCr is a nickel chrome. In the specified components, these heaters are made of wire or tape. SiC is a silicon carbide, and MoSi₂ is a molybdenum disilicide for which core heating elements are provided.

The type of heater is chosen together with the temperature performance, working environment and power part of the furnace. Therefore, when repairing, it is not enough to choose an element only in external dimensions. To choose a replacement, you need the initial marking, electrical parameters, connection scheme and working conditions.

Temperature class and operating temperature

When comparing offers, request separately the temperature performance of the furnace, the permissible long operating temperature and the short-term maximum with the permitted exposure. The 1800 °C designation itself does not confirm continuous operation at this temperature with any garden.

The heat-insulating material also has its own temperature class. It can not be taken as the guaranteed operating temperature of the entire furnace: the selected mode must be agreed simultaneously for heaters, sensors, lining, tooling and working environment.

Thermocouples, zones and heating program

The matrix of complete sets for 800 and 1000 °C shows thermocouples of type K, for 1200, 1400 and 1600 °C - type S, for 1700 and 1800 °C - type B. In a particular sentence, we additionally indicate the execution of the sensor, protective fittings and installation sites.

The thermocouple measures the temperature at the installation site. The controller uses its signal to control power. The accuracy of regulation at one point and the uniformity of temperature in terms of useful volume are different parameters. If the process requires a certain uniformity, set the allowable deviation, control area and test conditions with or without the garden.

The number of heating sides shows the location of the heaters; the number of independent zones is the number of separately regulated areas. UralInduktor usually has four thermocouples and corresponding control channels. The final scheme will agree on the size of the chamber and the placement of products.

For UI-MP and UI-MKP software PID regulators are provided, for UI-MPZA and UI-MWTP - touch panel and PLC. In UI-MPVP, the composition of the cabinet is selected by configuration. We agree on the number of programs and steps, the record of the temperature curve and the necessary locks. The presence of software management does not mean that archiving and remote access are included in any set.

Power, heating and cooling

Power in kW and electricity consumption per cycle in kWh characterize different values. To evaluate the cycle, you need a lot of products and equipment, initial and operating temperatures, heating, aging and cooling time. The capacities of the model series are indicated by the current configurations and can vary according to the technical task.

In the initial configurations of the five series, natural cooling is provided along with the furnace. The requirement for accelerated cooling or a given temperature reduction rate must be specified separately. The allowable heating and cooling rates are agreed for the product material and the selected lining.

What data to send for selection

  • The material of the products, the dimensions and the total mass of the plant together with the tooling; the scheme of support and placement.
  • Operating temperature, maximum temperature, heating and exposure time, cooling method.
  • Air, protective gas or vacuum; the purity of the environment and the composition of possible discharges from the garden.
  • Requirements for uniformity, number of zones, temperature curve recording and regime verification.
  • Restrictions on materials lining and contamination of products; access requirements for maintenance.
  • Power supply voltage, available power, location conditions and loading method.

According to these data, we will prepare a proposal with the design of the chamber and pod, materials, heaters, sensors, power, control system and an agreed start-up volume.

Choose a series or order a service

Send a technological task or a completed questionnaire - we will pick up the furnace and make a technical proposal.

Fill in the questionnaire and the calculation will be more accurate

Material and mass of the garden, temperature, cycle and atmosphere. The sheet can be attached to the application below instead of a detailed description of the task.

Download the questionnaire (.docx)
Selection and estimate

Get an equipment selection or a project calculation — fill in the form

An engineer will contact you, clarify the task and suggest a solution for your production process.

  • Equipment selection for your metal, operating mode and output
  • Cost, lead time and delivery arrangements
  • Response within one working day

Equipment selection and estimate request

Technical specification or equipment passport PDF, DOC, XLS, JPG or PNG, up to 10 MB
In touch with you

Let's discuss your task

  • Main contact number+7 (775) 853-40-95Sales department and engineering centre
  • Emailstasgross.ru@gmail.comResponse during the working day
  • Main office addressAstana, Saryarka district, Radisson hotel, office 4
  • Office hoursMon–Fri, 9:00–18:00GMT+5 (Astana)
Comparison of proposals

We'll compare commercial proposals
and offer our own option.

Send us another company's proposal — we will compare the equipment list, configuration and cost.