UralInduktor · metallurgical equipment manufacturing and supply
We will call back within 10 minutes
Heat treatment equipment

Thermal furnaces with a controlled protective atmosphere UI-MPZA

УИ-МПЗА protective-atmosphere furnaces — sealed chamber with inert gas supply for heat treatment without oxidation, temperature versions up to 1800 °C. 12-month warranty, turnkey putting into operation.

We will call back within 10 minutes

Quick estimate and consultation

An engineer will select a model for your metal and send a cost estimate.

model range
13 models
from УИ-МПЗА-3.8 to УИ-МПЗА-1280
temperature range
up to 1800 °C
800 °C, 1000 °C, 1200 °C, 1400 °C, 1600 °C, 1700 °C, 1800 °C
control accuracy
± 1 °C
programmable heating and holding stages
warranty
12 months
on supplied equipment
Configurations

Six versions of the furnace

Furnace in a protective atmosphere is available in several versions. Any execution is based on any model of the series.

№1 Furnaces in the protective atmosphere of UI-MPZA modification No1: Vacuum Furnace

Vacuum Oven

№2 UI-MPZA protective atmosphere furnaces modification No2: Two-door vacuum furnace

Two-door vacuum furnace

№3 Furnaces in a protective atmosphere UI-MPZA modification No3: Vacuum oven with lifting hoist

Vacuum oven with lifting hoist

№4 UI-MPZA protective furnace modification No4: Vacuum oven with touch screen on remote control

Vacuum oven with touch screen on remote control

№5 Furnaces in the protective atmosphere of UI-MPZA - modification No5: Vacuum furnace with increased atmospheric discharge inside the chamber

Vacuum oven with increased atmospheric discharge inside the chamber

№6 Furnaces in the protective atmosphere of UI-MPZA modification No6: Vacuum high-temperature furnace

High Temperature Vacuum Furnace

Applications

UI-MPSA helps to limit oxidation and maintain surface quality when heated. We select the gas, the design of the chamber or retort, the required tightness, purge and control of parameters for the material of the product and the permissible oxygen content. Pre-pumping can speed up the removal of air before filling with gas.

  • annealing and release of steels with restriction of oxidation
  • sintering of powder and ceramic materials
  • Heating of stainless and special alloys
  • processes in argon or nitrogen according to the technological map

Model range and specifications

ModelWorking chamber, mmVoltage, VPower, kW*
УИ-МПЗА-3.8150×150×1502204
УИ-МПЗА-4.5200×150×1502204
УИ-МПЗА-7.5300×200×1202206
УИ-МПЗА-12300×200×2003808–10
УИ-МПЗА-16400×250×16038010–12
УИ-МПЗА-36400×300×30038013–15
УИ-МПЗА-30500×300×20038012–14
УИ-МПЗА-45500×300×30038013–15
УИ-МПЗА-80500×400×40038016–18
УИ-МПЗА-125500×500×50038018–20
УИ-МПЗА-200800×500×50038040–45
УИ-МПЗА-7681200×800×80038050
УИ-МПЗА-12802000×800×80038090

The table shows the base range. Operating temperature, selected power and load dimensions including tooling are agreed for your process.

Additional sizes to specification

Working chamber, mmUsable volume, litresPower, kW*
300×300×3002712–14
400×200×2001610–12
400×400×4006415–17
600×500×50015025–28
700×500×50017530–35
1000×1000×1000100060

* Power may vary with temperature rating, load mass and composition, heating time, number of zones, atmosphere and options. The final value is stated in the technical proposal.

It is also possible to perform with the camera 1000 × 1000 × 1000 mm. A relevant plant matrix for this size indicates power 60 kW; the final value and power are specified by temperature, gardening and gas system.

How we select a configuration

  • composition and purity of working gas
  • Allowable level of residual oxygen
  • volume of the chamber, mass of the nozzle and circulation scheme
  • Do you need a vacuum pump just to pump out before blowing?

Temperature and control

The temperature is consistent with the inner chamber material, seals and gas. Oxygen, hydrogen, CO and other active or dangerous gases are considered only as a special project with a gas ramp, exhaust, locks and risk analysis.

Lining and heating elements

For UI-MPZA, fibrous versions are provided with the materials below and an additional heat-insulating layer. The choice of heaters and lining is agreed for the specific gas, temperature and composition of the discharge from the plant. The table does not mean that each option is compatible with any protective atmosphere.

Furnace class, °CFibrous lining materialHeating element option
800 / 1000Ceramic fibreFeCrAl wire
1200Alumina-based fibreNiCr wire or SiC
1400Alumina-based composite fibreSiC rods
1600High-purity alumina fibreMoSi₂ rods
1700High-purity alumina composite fibreMoSi₂ rods
1800Zirconia-based fibreMoSi₂ rods

FeCrAl: iron-chromium-aluminium alloy; NiCr: nickel-chromium alloy; SiC: silicon carbide; MoSi₂: molybdenum disilicide.

The temperature rating identifies the furnace class. Continuous operating temperature, holding time and maximum temperature with a load are specified separately. Insulation material alone does not determine these parameters.

How lining materials, heaters, thermocouples and controls are chosen — in a separate review: lining of heat treatment furnaces and the choice of heaters.

Thermocouples and heating programmes

Configurations use type K thermocouples for 800 and 1000 °C, type S for 1200, 1400 and 1600 °C, and type B for 1700 and 1800 °C. Sensor and protective fittings are selected for the operating environment.

The manufacturer's table provides a touch panel, programmable logic controller (PLC) and thyristor power control. We agree on the heating program, purge control, gas flow measurement and the list of locks; we fix the composition of these functions in the proposal.

The basic description provides for natural cooling along with the furnace. Cooling conditions, preservation of working environment and allowable opening temperature are agreed for your process.

Heat treatment furnace lining and heating element selection

Designs and additional options

  • Gas supply and control system
  • pre-vacuum
  • Lifting or rolling under for heavy landing
  • High Temperature Configuration
  • registration of temperature and environment parameters

Modifications 1, 2, 3, 4, 5 and 6 are available. The design, configuration and suitable size are agreed in the technical proposal.

Selection questions

How does a protective atmosphere differ from a vacuum?

In the first case, the heating takes place in the selected gas, in the second - with a given dilution. The choice depends on the material and the desired surface condition.

Why do you need a pump before gas supply?

It removes air from the chamber before filling with a protective environment. The need and depth of pumping is determined by technology.

Can the 1000 × 1000 × 1000 mm be made?

Yeah, it's an individual execution on technical specification. For the 1000 × 1000 × 1000 mm in the relevant matrix 60 kW; the total power , power and gas system are calculated for temperature and gardening.

Is it possible to use the same heaters in air, nitrogen and argon?

Compatibility is confirmed for the selected type and brand of heater, temperature and gas composition. The presence of nitrogen or argon in the list of working media of the series does not mean that any temperature performance is suitable for both gases.

What data is needed to choose lining in a protective atmosphere?

Specify the gas and its purity, the material of the nozzle, operating temperature, exposure and possible discharge when heated. In addition, we agree on the requirements for residual oxygen and contamination of the product.

What your technical proposal includes

  • chamber or retort with agreed tightness and useful dimensions
  • gas, purge circuit, flow, oxygen control, lock and hood
  • working temperature, power, supply composition, cost, time and commissioning

Testing, commissioning and warranty

Before shipment we check completeness, electrical and mechanical systems and interlocks with the equipment fully connected. The first complete heat-up is performed at the customer's site, taking the lining condition after transport into account. We commission the equipment, train staff and issue a completion certificate. Warranty is 12 months. Its start date is defined by the contract: shipment or signing the commissioning certificate.

Service in Kazakhstan

UralInduktor engineers diagnose, repair and upgrade heat treatment furnaces in Kazakhstan. We service heaters, sensors, control systems, lining, mechanical, gas and vacuum components.

Send us the material, the dimensions and weight of the load, the temperature and the cycle — we will select the configuration and calculate the cost.

Get selection and technical offer → Get a price

Complete cycle

One supplier — from project to service

We design for your technical process, manufacture, install on site, train operators and stay on the service.

  1. 01

    Selection and estimate

    1 working day · free of charge
  2. 02

    Production area design

    from 2 weeks
  3. 03

    Manufacturing

    30–60 days
  4. 04

    Delivery to site

    Astana and Kazakhstan we provide delivery
  5. 05

    Installation supervision and commissioning

    our team, agreed timeframe
  6. 06

    Staff training

    at your site, with a training certificate
  7. 07

    Service and upgrades

    12-month warranty and support

One contract, one point of responsibility. From the first calculation to the service after commissioning - all stages are carried out by our engineers for your facility.

Request a turnkey calculation →

Fill in the questionnaire and the calculation will be more accurate

Material and mass of the garden, temperature, cycle and atmosphere. The sheet can be attached to the application below instead of a detailed description of the task.

Download the questionnaire (.docx)
Selection and estimate

Get an equipment selection or a project calculation — fill in the form

An engineer will contact you, clarify the task and suggest a solution for your production process.

  • Equipment selection for your metal, operating mode and output
  • Cost, lead time and delivery arrangements
  • Response within one working day

Equipment selection and estimate request

Technical specification or equipment passport PDF, DOC, XLS, JPG or PNG, up to 10 MB
Why us

Why customers choose UralInduktor

A manufacturer with a complete engineering cycle: equipment selection, commissioning and service within one company.

Who it is for
  • Metallurgical enterprises
  • Foundries
  • Mechanical engineering
  • Aluminium production
  • Secondary metallurgy
  • Repair and mechanical workshops
  • Metal heat treatment and melting
01

Manufacturer in key product areas

We manufacture induction melting furnaces and heaters, shot blasting equipment, cooling systems and steel casting ladles, taking responsibility as the manufacturer.

02

Complete engineering cycle

Selection, design, delivery, installation, commissioning, training and service within one company.

03

Broad product portfolio

We address most metallurgical and foundry production requirements, from an individual furnace to a turnkey production area.

04

Practical technical experience

Operating since 2014. Completed projects of varying complexity and engineers with practical commissioning experience.

05

Fast supply of stock items

Some equipment is available from stock, reducing lead times for urgent requirements.

06

Warranty and support

12-month warranty on our own manufactured equipment. Ongoing post-warranty maintenance, spare parts and service.

In touch with you

Let's discuss your task

  • Main contact number+7 (775) 853-40-95Sales department and engineering centre
  • Emailstasgross.ru@gmail.comResponse during the working day
  • Main office addressAstana, Saryarka district, Radisson hotel, office 4
  • Office hoursMon–Fri, 9:00–18:00GMT+5 (Astana)
Comparison of proposals

We'll compare commercial proposals
and offer our own option.

Send us another company's proposal — we will compare the equipment list, configuration and cost.