Thermal furnaces with a controlled protective atmosphere UI-MPZA
УИ-МПЗА protective-atmosphere furnaces — sealed chamber with inert gas supply for heat treatment without oxidation, temperature versions up to 1800 °C. 12-month warranty, turnkey putting into operation.
Quick estimate and consultation
An engineer will select a model for your metal and send a cost estimate.
Six versions of the furnace
Furnace in a protective atmosphere is available in several versions. Any execution is based on any model of the series.
Two-door vacuum furnace
Vacuum oven with lifting hoist
Vacuum oven with touch screen on remote control
Vacuum oven with increased atmospheric discharge inside the chamber
High Temperature Vacuum Furnace
Applications
UI-MPSA helps to limit oxidation and maintain surface quality when heated. We select the gas, the design of the chamber or retort, the required tightness, purge and control of parameters for the material of the product and the permissible oxygen content. Pre-pumping can speed up the removal of air before filling with gas.
- annealing and release of steels with restriction of oxidation
- sintering of powder and ceramic materials
- Heating of stainless and special alloys
- processes in argon or nitrogen according to the technological map
Model range and specifications
| Model | Working chamber, mm | Voltage, V | Power, kW* |
|---|---|---|---|
| УИ-МПЗА-3.8 | 150×150×150 | 220 | 4 |
| УИ-МПЗА-4.5 | 200×150×150 | 220 | 4 |
| УИ-МПЗА-7.5 | 300×200×120 | 220 | 6 |
| УИ-МПЗА-12 | 300×200×200 | 380 | 8–10 |
| УИ-МПЗА-16 | 400×250×160 | 380 | 10–12 |
| УИ-МПЗА-36 | 400×300×300 | 380 | 13–15 |
| УИ-МПЗА-30 | 500×300×200 | 380 | 12–14 |
| УИ-МПЗА-45 | 500×300×300 | 380 | 13–15 |
| УИ-МПЗА-80 | 500×400×400 | 380 | 16–18 |
| УИ-МПЗА-125 | 500×500×500 | 380 | 18–20 |
| УИ-МПЗА-200 | 800×500×500 | 380 | 40–45 |
| УИ-МПЗА-768 | 1200×800×800 | 380 | 50 |
| УИ-МПЗА-1280 | 2000×800×800 | 380 | 90 |
The table shows the base range. Operating temperature, selected power and load dimensions including tooling are agreed for your process.
Additional sizes to specification
| Working chamber, mm | Usable volume, litres | Power, kW* |
|---|---|---|
| 300×300×300 | 27 | 12–14 |
| 400×200×200 | 16 | 10–12 |
| 400×400×400 | 64 | 15–17 |
| 600×500×500 | 150 | 25–28 |
| 700×500×500 | 175 | 30–35 |
| 1000×1000×1000 | 1000 | 60 |
* Power may vary with temperature rating, load mass and composition, heating time, number of zones, atmosphere and options. The final value is stated in the technical proposal.
It is also possible to perform with the camera 1000 × 1000 × 1000 mm. A relevant plant matrix for this size indicates power 60 kW; the final value and power are specified by temperature, gardening and gas system.
How we select a configuration
- composition and purity of working gas
- Allowable level of residual oxygen
- volume of the chamber, mass of the nozzle and circulation scheme
- Do you need a vacuum pump just to pump out before blowing?
Temperature and control
The temperature is consistent with the inner chamber material, seals and gas. Oxygen, hydrogen, CO and other active or dangerous gases are considered only as a special project with a gas ramp, exhaust, locks and risk analysis.
Lining and heating elements
For UI-MPZA, fibrous versions are provided with the materials below and an additional heat-insulating layer. The choice of heaters and lining is agreed for the specific gas, temperature and composition of the discharge from the plant. The table does not mean that each option is compatible with any protective atmosphere.
| Furnace class, °C | Fibrous lining material | Heating element option |
|---|---|---|
| 800 / 1000 | Ceramic fibre | FeCrAl wire |
| 1200 | Alumina-based fibre | NiCr wire or SiC |
| 1400 | Alumina-based composite fibre | SiC rods |
| 1600 | High-purity alumina fibre | MoSi₂ rods |
| 1700 | High-purity alumina composite fibre | MoSi₂ rods |
| 1800 | Zirconia-based fibre | MoSi₂ rods |
FeCrAl: iron-chromium-aluminium alloy; NiCr: nickel-chromium alloy; SiC: silicon carbide; MoSi₂: molybdenum disilicide.
The temperature rating identifies the furnace class. Continuous operating temperature, holding time and maximum temperature with a load are specified separately. Insulation material alone does not determine these parameters.
How lining materials, heaters, thermocouples and controls are chosen — in a separate review: lining of heat treatment furnaces and the choice of heaters.
Thermocouples and heating programmes
Configurations use type K thermocouples for 800 and 1000 °C, type S for 1200, 1400 and 1600 °C, and type B for 1700 and 1800 °C. Sensor and protective fittings are selected for the operating environment.
The manufacturer's table provides a touch panel, programmable logic controller (PLC) and thyristor power control. We agree on the heating program, purge control, gas flow measurement and the list of locks; we fix the composition of these functions in the proposal.
The basic description provides for natural cooling along with the furnace. Cooling conditions, preservation of working environment and allowable opening temperature are agreed for your process.
Heat treatment furnace lining and heating element selection
Designs and additional options
- Gas supply and control system
- pre-vacuum
- Lifting or rolling under for heavy landing
- High Temperature Configuration
- registration of temperature and environment parameters
Modifications 1, 2, 3, 4, 5 and 6 are available. The design, configuration and suitable size are agreed in the technical proposal.
Selection questions
How does a protective atmosphere differ from a vacuum?
In the first case, the heating takes place in the selected gas, in the second - with a given dilution. The choice depends on the material and the desired surface condition.
Why do you need a pump before gas supply?
It removes air from the chamber before filling with a protective environment. The need and depth of pumping is determined by technology.
Can the 1000 × 1000 × 1000 mm be made?
Yeah, it's an individual execution on technical specification. For the 1000 × 1000 × 1000 mm in the relevant matrix 60 kW; the total power , power and gas system are calculated for temperature and gardening.
Is it possible to use the same heaters in air, nitrogen and argon?
Compatibility is confirmed for the selected type and brand of heater, temperature and gas composition. The presence of nitrogen or argon in the list of working media of the series does not mean that any temperature performance is suitable for both gases.
What data is needed to choose lining in a protective atmosphere?
Specify the gas and its purity, the material of the nozzle, operating temperature, exposure and possible discharge when heated. In addition, we agree on the requirements for residual oxygen and contamination of the product.
What your technical proposal includes
- chamber or retort with agreed tightness and useful dimensions
- gas, purge circuit, flow, oxygen control, lock and hood
- working temperature, power, supply composition, cost, time and commissioning
Testing, commissioning and warranty
Before shipment we check completeness, electrical and mechanical systems and interlocks with the equipment fully connected. The first complete heat-up is performed at the customer's site, taking the lining condition after transport into account. We commission the equipment, train staff and issue a completion certificate. Warranty is 12 months. Its start date is defined by the contract: shipment or signing the commissioning certificate.
Service in Kazakhstan
UralInduktor engineers diagnose, repair and upgrade heat treatment furnaces in Kazakhstan. We service heaters, sensors, control systems, lining, mechanical, gas and vacuum components.
Send us the material, the dimensions and weight of the load, the temperature and the cycle — we will select the configuration and calculate the cost.
One supplier — from project to service
We design for your technical process, manufacture, install on site, train operators and stay on the service.
- 01
Selection and estimate
- 02
Production area design
- 03
Manufacturing
- 04
Delivery to site
- 05
Installation supervision and commissioning
- 06
Staff training
- 07
Service and upgrades
One contract, one point of responsibility. From the first calculation to the service after commissioning - all stages are carried out by our engineers for your facility.
Request a turnkey calculation →Fill in the questionnaire and the calculation will be more accurate
Material and mass of the garden, temperature, cycle and atmosphere. The sheet can be attached to the application below instead of a detailed description of the task.
Get an equipment selection or a project calculation — fill in the form
An engineer will contact you, clarify the task and suggest a solution for your production process.
- Equipment selection for your metal, operating mode and output
- Cost, lead time and delivery arrangements
- Response within one working day
Why customers choose UralInduktor
A manufacturer with a complete engineering cycle: equipment selection, commissioning and service within one company.
Manufacturer in key product areas
We manufacture induction melting furnaces and heaters, shot blasting equipment, cooling systems and steel casting ladles, taking responsibility as the manufacturer.
Complete engineering cycle
Selection, design, delivery, installation, commissioning, training and service within one company.
Broad product portfolio
We address most metallurgical and foundry production requirements, from an individual furnace to a turnkey production area.
Practical technical experience
Operating since 2014. Completed projects of varying complexity and engineers with practical commissioning experience.
Fast supply of stock items
Some equipment is available from stock, reducing lead times for urgent requirements.
Warranty and support
12-month warranty on our own manufactured equipment. Ongoing post-warranty maintenance, spare parts and service.
Let's discuss your task
- Main contact number+7 (775) 853-40-95
- Main office addressAstana, Saryarka district, Radisson hotel, office 4
- Office hoursMon–Fri, 9:00–18:00
We'll compare commercial proposals
and offer our own option.
Send us another company's proposal — we will compare the equipment list, configuration and cost.