Chamber thermal electric furnaces UI-MKP (SNO / SNZ)
УИ-МКП chamber furnaces — horizontal loading through a hinged door, spacious working chamber from 200×150×150 to 2000×800×800 mm, from 4 to 90 kW, temperature versions up to 1800 °C. 12-month warranty.
Quick estimate and consultation
An engineer will select a model for your metal and send a cost estimate.
Six versions of the chamber furnace
The chamber furnace UI-MKP is available in six versions - according to the type of the console, the format of the case, the door mechanism, the air circulation system and the method of control. Any execution is based on any model of the series.
Compact Oven
Vertical oven with double door mechanism
Vertical Oven
Furnace with forced mixing of air
Furnace with remote control via ARM
Applications
UI-MCP is chosen for batches of parts and materials that are convenient to load from the front on the under, shelves or special equipment. The chamber layout allows you to adapt the location of the heaters, the number of zones and the mechanics of the door to a specific production process.
- Release and annealing of steel parts
- firing and calcination of ceramic and mineral materials
- heating of tools, shapes and stamping equipment
- Research and control cycles
Model range and specifications
| Model | Working chamber, mm | Voltage, V | Power, kW* |
|---|---|---|---|
| УИ-МКП-4.5 | 200×150×150 | 220 | 4 |
| УИ-МКП-7.2 | 300×200×120 | 220 | 6 |
| УИ-МКП-12 | 300×200×200 | 380 | 8–10 |
| УИ-МКП-16 | 400×250×160 | 380 | 10–12 |
| УИ-МКП-36 | 400×300×300 | 380 | 13–15 |
| УИ-МКП-30 | 500×300×200 | 380 | 12–14 |
| УИ-МКП-45 | 500×300×300 | 380 | 13–15 |
| УИ-МКП-80 | 500×400×400 | 380 | 16–18 |
| УИ-МКП-125 | 500×500×500 | 380 | 18–20 |
| УИ-МКП-200 | 800×500×500 | 380 | 40–45 |
| УИ-МКП-768 | 1200×800×800 | 380 | 50 |
| УИ-МКП-1280 | 2000×800×800 | 380 | 90 |
The table shows the base range. Operating temperature, selected power and load dimensions including tooling are agreed for your process.
Additional sizes to specification
| Working chamber, mm | Usable volume, litres | Power, kW* |
|---|---|---|
| 300×300×300 | 27 | 12–14 |
| 400×200×200 | 16 | 10–12 |
| 400×400×400 | 64 | 15–17 |
| 600×500×500 | 150 | 25–28 |
| 700×500×500 | 175 | 30–35 |
| 1000×1000×1000 | 1000 | 60 |
* Power may vary with temperature rating, load mass and composition, heating time, number of zones, atmosphere and options. The final value is stated in the technical proposal.
How we select a configuration
- width, depth and height of the garden with technological gaps
- loading method: manual, trolley, crane or manipulator
- permissible load under
- number of control zones and the need for convection
Temperature and control
Different temperatures are available; a specific long operating temperature is confirmed with regard to the selected chamber, heaters and thermal insulation. Accuracy *± 1 °C refers to sensor-point control and does not automatically mean the same equilibrium in all volume.
Lining and heating elements
The fiber elements of the lining UI-MKP are selected together with heaters, chamber sizes and equipment. For different temperature versions, the following materials and an additional fibrous insulating layer are provided. The design of the pod and supports agree on the load.
| Furnace class, °C | Fibrous lining material | Heating element option |
|---|---|---|
| 800 / 1000 | Ceramic fibre | FeCrAl wire |
| 1200 | Alumina-based fibre | NiCr wire or SiC |
| 1400 | Alumina-based composite fibre | SiC rods |
| 1600 | High-purity alumina fibre | MoSi₂ rods |
| 1700 | High-purity alumina composite fibre | MoSi₂ rods |
| 1800 | Zirconia-based fibre | MoSi₂ rods |
FeCrAl: iron-chromium-aluminium alloy; NiCr: nickel-chromium alloy; SiC: silicon carbide; MoSi₂: molybdenum disilicide.
The temperature rating identifies the furnace class. Continuous operating temperature, holding time and maximum temperature with a load are specified separately. Insulation material alone does not determine these parameters.
How lining materials, heaters, thermocouples and controls are chosen — in a separate review: lining of heat treatment furnaces and the choice of heaters.
Thermocouples and heating programmes
Configurations use type K thermocouples for 800 and 1000 °C, type S for 1200, 1400 and 1600 °C, and type B for 1700 and 1800 °C. Sensor and protective fittings are selected for the operating environment.
A multi-stage heating and aging program is performed by a PID regulator; the power is regulated by a thyristor unit. When choosing the number of zones, we take into account the length of the chamber and the layout of the garden. The number of heating sides is agreed separately from the number of independently controlled zones.
The base configuration uses natural cooling with the furnace. A specified cooling rate or accelerated cycle must be included in the technical requirements so a suitable configuration can be selected.
Heat treatment furnace lining and heating element selection
Designs and additional options
- Freestanding Control Cabinet
- Compact Housing
- Different Door Mechanisms
- Touch Panel
- Forced Convection on technical specification
- ARM and registration of parameters
Modifications 1, 2, 3, 4, 5 and 6 are available. The design, configuration and suitable size are agreed in the technical proposal.
Selection questions
How to choose the chamber size?
We take into account the product, equipment, location of heaters and technological gaps. For a basket with details, we estimate the total mass of the garden.
Can I change the door and load?
Yeah. We will offer a swing or lift door and agree on loading manually, with a trolley or with a manipulator.
Can I add temperature registration?
Yeah. The recorder or recorder stores the temperature curve for subsequent reporting.
Is it possible to place parts directly on the fibrous lining?
We define the detail scheme separately. To calculate the pod, you need a mass of the entire garden together with the equipment and the area of the supports. The thermal insulation material does not set the permissible load on the under.
Three sides of the heating mean three control areas?
Oh, no. The heating sides describe the location of the heaters. The independent zone has its own control channel; the number of such channels is indicated separately.
What your technical proposal includes
- the size of the chamber and the layout of the garden with snap-in
- type of door and loading, number of zones, operating temperature and installed capacity
- equipment, site requirements, cost, time and commissioning
Testing, commissioning and warranty
Before shipment we check completeness, electrical and mechanical systems and interlocks with the equipment fully connected. The first complete heat-up is performed at the customer's site, taking the lining condition after transport into account. We commission the equipment, train staff and issue a completion certificate. Warranty is 12 months. Its start date is defined by the contract: shipment or signing the commissioning certificate.
Service in Kazakhstan
UralInduktor engineers diagnose, repair and upgrade heat treatment furnaces in Kazakhstan. We service heaters, sensors, control systems, lining, mechanical, gas and vacuum components.
Send us the material, the dimensions and weight of the load, the temperature and the cycle — we will select the configuration and calculate the cost.
One supplier — from project to service
We design for your technical process, manufacture, install on site, train operators and stay on the service.
- 01
Selection and estimate
- 02
Production area design
- 03
Manufacturing
- 04
Delivery to site
- 05
Installation supervision and commissioning
- 06
Staff training
- 07
Service and upgrades
One contract, one point of responsibility. From the first calculation to the service after commissioning - all stages are carried out by our engineers for your facility.
Request a turnkey calculation →Fill in the questionnaire and the calculation will be more accurate
Material and mass of the garden, temperature, cycle and atmosphere. The sheet can be attached to the application below instead of a detailed description of the task.
Get an equipment selection or a project calculation — fill in the form
An engineer will contact you, clarify the task and suggest a solution for your production process.
- Equipment selection for your metal, operating mode and output
- Cost, lead time and delivery arrangements
- Response within one working day
Why customers choose UralInduktor
A manufacturer with a complete engineering cycle: equipment selection, commissioning and service within one company.
Manufacturer in key product areas
We manufacture induction melting furnaces and heaters, shot blasting equipment, cooling systems and steel casting ladles, taking responsibility as the manufacturer.
Complete engineering cycle
Selection, design, delivery, installation, commissioning, training and service within one company.
Broad product portfolio
We address most metallurgical and foundry production requirements, from an individual furnace to a turnkey production area.
Practical technical experience
Operating since 2014. Completed projects of varying complexity and engineers with practical commissioning experience.
Fast supply of stock items
Some equipment is available from stock, reducing lead times for urgent requirements.
Warranty and support
12-month warranty on our own manufactured equipment. Ongoing post-warranty maintenance, spare parts and service.
Let's discuss your task
- Main contact number+7 (775) 853-40-95
- Main office addressAstana, Saryarka district, Radisson hotel, office 4
- Office hoursMon–Fri, 9:00–18:00
We'll compare commercial proposals
and offer our own option.
Send us another company's proposal — we will compare the equipment list, configuration and cost.