IGBT module FZ400R12KS4

FZ400R12KS4 contains one IGBT with reverse diode. The VCES limit voltage is 1200 V, the allowable direct current of the collector is 400 A at the temperature of the housing Tc 70 °C.

Maximum voltage VCES
1200 V
Permissible direct current
400 A at Tc = 70 °C
Scheme
Single Key
Price on request

The cost and delivery time are specified for the selected execution.

FZ400R12KS4

The module is made according to the scheme of a single key. The base has dimensions 106,4 × 61,4 mm. When checking the replacement, compare the internal scheme and the location of the conclusions: the same body size is not enough.

Technical specifications

ParameterValueTerms and Conditions
Internal schemeSingle Key —
Maximum voltage collectoremitter1200 Vmax.Tj = 25 °C
Allowable direct current collector400 APermissible permanentTc = 70 °C; Tj max = 150 °C
Permissible DC at Tc 25 °C510 APermissible permanentTc = 25 °C; Tj max = 150 °C
Maximum pulse current of the collector800 Amax.Pulse 1 ms
Limit voltage shutteremitter±20 VLimits—
Saturation voltage VCE(sat)3,2 VHe's a type.Ic = 400 A; VGE = 15 V; Tj = 25 °C
Saturation voltage VCE(sat)3,7 Vmax.Ic = 400 A; VGE = 15 V; Tj = 25 °C
Maximum dissipated power2500 WLimitsTc 25 °C; per IGBT; Tj max 150 °C
Thermal resistance crystalhull0,05 K/Wmax.For one IGBT
Crystal temperature during switching−40…+125 °CPermissible range—
Crystal Limit Temperature150 °Cmax.Limit under conditions of absolute maximum values
Storage temperature−40…+125 °CRange—
Insulation test voltage2,5 kV ACOngoing1 mines at 50 Hz
Shutter Charge4,2 ClHe's a type.VGE: from -− 15 to +15 V
Internal shutter resistor resistance1,3 OmHe's a type.Tj = 25 °C
Inlet capacity26 NFHe's a type.VCE = 25 V; VGE = 0 V; f = 1 MHz; Tj = 25 °C
Passing Capacity1,7 NFHe's a type.VCE = 25 V; VGE = 0 V; f = 1 MHz; Tj = 25 °C
Length base width106,4 × 61,4 mmNominal dimensionsAccording to the drawing of the body
Weight340 gHe's a type.—
Energy Inclusion22 mJHe's a type.Ic = 400 A; VCE = 600 V; VGE = ±15 V; Tj = 125 °C; RGon = 2,2 Om; Ls = 85 nG; di/dt = 4000 A/mx
Power off29 mJHe's a type.Ic = 400 A; VCE = 600 V; VGE = ±15 V; Tj = 125 °C; RGoff = 2,2 Ω; Ls = 85 nH

Tc is the temperature of the shell, Tj is the temperature of the crystal. "Type." means the default value, "max." - the maximum. For half-bridges, current and scattering power are indicated on one IGBT. Limits are not set by the recommended operating mode.