UralInduktor · metallurgical equipment manufacturing and supply
We will call back within 10 minutes

Replaceable immersion thermocouples; the rod and contact head are selected separately.

Immersion thermocouples and measuring rods

A set — tailored to your taskPrice on request
  • Purpose: contact measurement of melt temperature
  • Consumable part: immersion thermocouple tip
  • Reusable part: rod and contact assembly of the selected version

Description

The replaceable immersion thermocouple, contact head and rod connect the instrument to the melt. When replacing consumables, not only the dimensions but also the electrical characteristics of the entire circuit must match.

Parameters and configuration

AppointmentContact measurement of melt temperature
Consumable partImmersion thermocouple tip
Reusable partRod and contact assembly of the selected version
Thermocouple typeMatched to the instrument, metal and range
Dimensions and fitConfirmed by a sample or drawing
Tip service lifePer the instructions of the specific product; reuse is not intended

Compatibility is checked by thermocouple type, polarity, contacts and fit. The rod length is selected for the workplace; the quantity and packaging of the tips are specified in the order.

Identical tubes can have different sensors

Identical paper tubes do not mean an identical sensor design. Tips may differ in thermocouple type, polarity, contacts and operating temperature range.

In your request, state the thermocouple type set in the meter settings and the tip marking. If the marking is unknown, send photos of the packaging, both ends of the tip and the contact head of the rod.

The pole is chosen to suit the workplace

The length must allow the established procedure to be performed from the intended working position. The design of the furnace or ladle, the location of the platform and access to the metal are important. Excessive length is also inconvenient: the load on the operator and the risk of mechanical damage increase.

When replacing the contact assembly, check the fit of the tip, the condition of the insulation and that the conductors match. Poor contact cannot be compensated for by increasing the immersion depth or the hold time.

Acceptance of a consumables batch

  • Verify the designation, packaging and agreed version.
  • Inspect the tubes and contact parts for damage.
  • Check the fit on the standard rod.
  • Perform control measurements according to the procedure adopted at the plant.
  • Check the requirements for dry storage and handling of the tips.

Service life and consumption of tips

The immersion depth, measurement time and permissibility of reuse must not be carried over from one tip to another. If a product is declared as single-use, its reuse is not included in supply calculations.

Consumption is planned based on the number of control measurements, the accepted reserve and the stability of the procedure. The number of tips per box and the minimum batch are confirmed when ordering.

To get started, we need

  • Instrument and installed thermocouple type
  • Metal and operating temperature
  • Photo of the tip, contacts and packaging
  • Rod length and consumables requirement

For the melting area: induction melting furnaces and steel-pouring ladles.

Related instruments and consumables

Frequently Asked Questions

Questions about selection

If you did not find an answer — call us, and an engineer will review your task.

Will the tip fit an instrument that is already installed?

Compatibility is confirmed by thermocouple type, contacts, fit and the instrument documentation. The label «for liquid metal» does not guarantee interchangeability.

Can I order just the rod?

Yes, rod selection can be considered separately. Information about the instrument, tip and workplace is required; the final version is agreed in the proposal.

UralInduktor · since 2014

Solutions for your production tasks

A full cycle of work with equipment for foundry, metallurgical and machine-building enterprises.

Not sure where to start? Let's discuss your task.

Discuss your task
Selection and estimate

Get an equipment selection or a project calculation — fill in the form

An engineer will contact you, clarify the task and suggest a solution for your production process.

  • Equipment selection for your metal, operating mode and output
  • Cost, lead time and delivery arrangements
  • Response within one working day

Equipment selection and estimate request

Technical specification or equipment passport PDF, DOC, XLS, JPG or PNG, up to 10 MB
In touch with you

Let's discuss your task

  • Main contact number+7 (775) 853-40-95Sales department and engineering centre
  • Emailstasgross.ru@gmail.comResponse during the working day
  • Main office addressAstana, Saryarka district, Radisson hotel, office 4
  • Office hoursMon–Fri, 9:00–18:00GMT+5 (Astana)
Comparison of proposals

We'll compare commercial proposals
and offer our own option.

Send us another company's proposal — we will compare the equipment list, configuration and cost.